Guide · Safety

Generators save power and take lives

A portable generator's exhaust can kill in minutes. The CPSC counted 770 carbon monoxide deaths from generators in 2011–2021, most of them at home and in winter. These are the rules that prevent them.

Facts checked November 12, 2026 against the sources listed below

The toll

770Generator CO deaths, 2011–2021 (CPSC)
81%Of them at home
43%From November to February
17%Of engine-tool CO deaths had an alarm present

The Consumer Product Safety Commission's 2022 report counted 900 carbon monoxide deaths from engine-driven tools in 2011–2021; 770 of them, 86%, came from portable generators alone. Power outages were behind 114 of the incidents and 157 deaths, and 7% of the deaths involved a generator that was outdoors but too close to an opening. The counts for 2020 and 2021 were still incomplete when it was published. Across all sources, the CDC says more than 400 Americans die from unintentional carbon monoxide poisoning not linked to fires every year, with more than 100,000 emergency-room visits.

Where it goes

Outdoors, at least 20 feet away. The CDC, CPSC and Ready.gov agree: run a portable generator outdoors, at least 20 feet from windows, doors, vents and attached garages, with the exhaust pointed away from the house. Never in a home, garage, basement, crawlspace or shed, even with the doors and windows open.

The CDC advises an extension cord longer than 20 feet so the generator can sit far enough away. Keep fuel outdoors too, and let the engine cool before refuelling.

Alarms and symptoms

Put carbon monoxide alarms on every level of the home and outside sleeping areas, with batteries or battery backup so they work when the power is out, and test them monthly (CPSC, CDC). Interconnected alarms, which all sound together, are best.

The most common symptoms are headache, dizziness, weakness, nausea, vomiting, chest pain and confusion. People who are asleep or have been drinking can die before they have symptoms (CDC). If an alarm sounds or anyone feels sick, get everyone outside to fresh air immediately, then call 911.

Connecting it safely

Plug appliances into the generator with heavy-duty outdoor extension cords (Ready.gov). Never plug a generator into a wall outlet or wire it into the house without a properly installed transfer switch: it can feed power back onto the utility's lines, known as backfeeding, which can electrocute line workers and neighbours (Wisconsin DATCP). A licensed electrician installs transfer switches. To size one, use the generator calculator.

The coming rule

There is still no mandatory federal safety standard for portable generators. In April 2023 the CPSC proposed one that would limit carbon monoxide emissions and require generators to shut off automatically; its regulatory agenda, published in August 2026, still lists it at the final-rule stage. Some generators already carry an automatic CO shutoff under a voluntary industry standard, but the CPSC's report notes a fatal incident involving one advertised as meeting it, so a shutoff is no reason to run one closer to the house.

Questions

Quick answers

How far should a generator be from the house?

At least 20 feet from windows, doors, vents and attached garages, with the exhaust pointed away from the home (CDC, CPSC, Ready.gov). Never run one inside a home, garage, basement or crawlspace, even with doors and windows open.

How many people die from generator carbon monoxide?

The CPSC counted 770 deaths from carbon monoxide from portable generators in 2011–2021, out of 900 from all engine-driven tools. It has described the toll as about 85 to nearly 100 deaths a year. Most happened at home, and 43% from November to February.

What are the symptoms of carbon monoxide poisoning?

Headache, dizziness, weakness, nausea, vomiting, chest pain and confusion. People who are asleep or have been drinking can die before they notice any symptoms (CDC). If a CO alarm sounds, get everyone outside to fresh air, then call 911.

Do I need a carbon monoxide alarm?

Yes: on every level of the home and outside sleeping areas, with battery power or battery backup so it works in an outage (CPSC, CDC, Ready.gov). In the CPSC's study only 17% of the engine-tool CO deaths had an alarm present.

Is there a federal safety standard for portable generators?

Not a mandatory one yet. The CPSC proposed in 2023 to limit generators' carbon monoxide emissions and require automatic shutoff; its regulatory agenda still lists the rule at the final-rule stage.